sr9009-notes.peptides6908.com › Guide › Sr9009 Identity And Mechanism — Quick Reference

Sr9009 Identity And Mechanism — Quick Reference

By Editorial Desk · published 2025-02-12 · last reviewed 2025-04-06 · Guide

LC-MS/MS comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.

Updated 2025-04-06. Numbers and descriptions here follow the published literature rather than marketing material.

SR9009 Identity and Mechanism

SR9009 is a synthetic small molecule that acts on the nuclear receptors REV-ERBα and REV-ERBβ. These receptors are part of the circadian clock machinery and normally repress transcription of certain target genes. In laboratory research, SR9009 is used as a chemical tool to study how REV-ERB activity influences metabolism, inflammation, and daily biological rhythms. The compound is not an approved medicine, and its effects in humans remain largely uncharacterized. It is often described as an investigational agent rather than a therapeutic product.

REV-ERB proteins typically suppress gene expression by recruiting corepressor complexes to DNA response elements. SR9009 binds these receptors and strengthens that repressive action in cell-based assays. Studies in rodents have reported changes in lipid handling, mitochondrial function, and exercise capacity after treatment. Such findings are often cited as evidence for metabolic effects, but species differences and limited pharmacokinetic data make direct translation to humans uncertain. Researchers continue to examine which effects are robust and which depend on specific experimental conditions.

SR9009 is frequently discussed alongside other REV-ERB ligands, including synthetic agonists and natural heme-related molecules. Its selectivity for REV-ERB over related nuclear receptors has been measured in binding and reporter assays, though off-target activity at higher concentrations is possible. The compound is prohibited in sport by the World Anti-Doping Agency, and it is not approved for any medical use in major jurisdictions. Products sold online may be labeled as research chemicals, and their identity and purity are not guaranteed by regulatory review.

SR9009 Handling and Quality Control

Identity and purity of SR9009 samples are usually checked with chromatographic and spectrometric methods. High-performance liquid chromatography can separate the compound from related impurities, while mass spectrometry provides molecular mass confirmation. Nuclear magnetic resonance spectroscopy may be used for structural verification in research settings. No single method proves biological activity, and certificates of analysis should be reviewed alongside raw data. Independent testing is often needed because online products vary widely.

SR9009 stability depends on temperature, moisture, light, and solvent. Solid material is generally kept cool and dry, while solutions may require protection from repeated warming and cooling. Degradation can appear as color changes, precipitate, or new chromatographic peaks. Researchers should follow supplier instructions and their own stability data. Long-term storage conditions for human use have not been established because the compound lacks approved clinical formulation.

SR9009 is supplied as a solid research chemical, often in milligram quantities. Laboratories typically weigh it in a controlled environment because fine powders can disperse. Stock solutions are commonly prepared in dimethyl sulfoxide and stored in small aliquots to reduce freeze-thaw cycles. Personal protective equipment and chemical fume hoods are standard when handling unknown or potent compounds. These practices address laboratory safety rather than human use.

Sr9009 at a glance

PropertyValueNotes
Common nameSR9009Also marketed informally as Stenabolic
Chemical classSynthetic REV-ERB agonistBinds REV-ERBα and REV-ERBβ
Molecular formulaC24H30ClN3O4SApproximate molecular weight 492 g/mol
CAS Registry Number1379686-30-2Identifier for the parent compound
Regulatory statusNot approved for human useProhibited in sport by WADA

Analytical and Handling Considerations

Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.

SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.

For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.

Related pages on this site

Analytical Detection and Stability

Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.

Regulatory treatment of SR9009 varies by country and region. It is not approved as a pharmaceutical, and several jurisdictions restrict its sale for human consumption. Some authorities classify it as a research chemical, a prescription-only substance, or a prohibited performance-enhancing agent in sport. Purchasers may encounter certificates of analysis, but these documents do not guarantee identity, purity, or legality. In research settings, institutional safety reviews and controlled procurement help ensure that materials are handled under appropriate oversight. The absence of harmonized rules means that legal status can change and requires verification.

Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.

Supporting material

Cervical drug delivery serves as a route for compounds to prevent and treat sexually transmitted diseases (STDs). Prevention of STDs for women can be achieved by administering preventative compounds into the vaginal canal prior to intercourse. One method researched is the use of a CAP technology that remains stable in the vaginal environment, but breaks down in the presence of human semen, releasing a drug to destroy STDs. This application of cervical drug delivery would be useful for prevention of STDs in women without interfering with the bodily environment until there is potential for infection. STDs can also be treated through cervical drug delivery methods. Antibiotics for STD treatment are often administered into the vagina in the form of creams or gels.

Mouse MA-10 cells respond to 5-oxo-ETE but lack OXER1. It has been suggested that these cells' responses to 5-oxo-ETE are mediated by an ortholog to OXER1, mouse niacin receptor 1, Niacr1, which is a G protein-coupled receptor for niacin, or, alternatively, by one or more of the mouse hydroxycarboxylic acid (HCA) family of the G protein-coupled receptors, HCA1 (GPR81), HCA2 (GPR109A), and HCA3 (GPR109B), which are G protein-coupled receptors for fatty acids.

APHL works with public health partners to build the foundation for quality testing, comprehensive standards and integrated public health laboratory systems. One of the initiatives, the Laboratory System Improvement Program, provides individual assessments of public health laboratory systems that include engaging stakeholders for system improvement, performance, implementation of strategies and continual evaluation. APHL also collaborates on the National Laboratory System project to build a public-private network of laboratories nationwide. APHL monitors trends in public health laboratory diagnostics, personnel and infrastructure in order to create quality assurance standards. By using these data points to benchmark individual labs against national norms, APHL is able to home in on key issues and help raise the standard of laboratory systems. Member labs have access to research and survey data online, which enables them to leverage new information quickly to identify promising strategies and practices.

5-HTP has been used medically and as a supplement under the name oxitriptan in the treatment of depression and for certain other indications. As of 2025, there are no current FDA approved medications containing 5-HTP. It can be potentiated in combination with a peripherally selective aromatic L-amino acid decarboxylase (AAAD) inhibitor such as carbidopa or benserazide. These agents increase the strength and duration of oxitriptan. An investigational combination formulation is oxitriptan/carbidopa.

Sources: en.wikipedia.org

Supporting material

Apryll Marie Stalcup is an American chemist who is Professor and was the Director of the Irish Separation Science Cluster at Dublin City University. She was awarded the 2021 Chromatography Forum of the Delaware Valley Stephen Dal Nogare Award, the 2015 American Microchemical Society Benedetti Pichler Award and named in the 2016 Power List of the Top 50 Women Analytical Scientists worldwide. Her research considers surface-confined ionic liquids and chiral separations.

"Bad and Boujee" is a song by American hip-hop group Migos featuring American rapper Lil Uzi Vert. Written alongside producer Metro Boomin and co-producer G Koop, it was originally released to the Quality Control Music YouTube channel on August 27, 2016 before being officially released on October 28 by Quality Control Music, 300 Entertainment, and Atlantic Records as the lead single from the group's second studio album Culture (2017). In late December 2016, "Bad and Boujee" became an Internet phenomenon, spawning many memes with the lyrics "rain drop, drop top". This viral trend, combined with Donald Glover's shoutout at the 2017 Golden Globes, would help its commercial performance and cause the song to spike into the top ten and later peak at number one on the US Billboard Hot 100 for the week of January 21, 2017, making it the first number one single for both Migos and Lil Uzi Vert. There were also many memes about member Takeoff's omission from the song. The single received a nomination for Best Rap Performance at the 60th Annual Grammy Awards. The track has acquired over 1 billion Spotify plays as of August 2025.

As filaments grow, the pool of available G-actin molecules is managed by G-actin-binding proteins such as profilin and thymosin β-4. Profilin ensures a supply of available actin-ATP by binding to ADP-bound G-actin and promoting the exchange of ADP for ATP. Profilin's binding to the actin molecule physically blocks its addition to a filament's (−) end, but permits it to join the (+) end. Once the actin-ATP has joined the filament, profilin releases it. As formins promote the nucleation and extension of new actin filaments, they recruit profilin to the area, increasing the local concentration of actin-ATP to boost filament growth. In contrast, thymosin β-4 binds and sequesters actin-ATP, preventing it from joining a microfilament. Once an actin fiber is established, the dynamics of its growth or collapse are influenced by numerous proteins. Existing strands can be interrupted by filament cleaving proteins, such as cofilin and gelsolin. Cofilin binds along two actin-ADP molecules in a filament, forcing a movement that destabilizes the filament and causes it to break. Gelsolin inserts itself between actin molecules in a filament, disrupting the filament. After the filament breaks, gelsolin remains attached to the new (+) end, preventing it from growing, thus forcing its disassembly.

Sources: en.wikipedia.org

Frequently asked questions

What is SR9009?

SR9009 is a synthetic research compound that binds and modulates the nuclear receptors REV-ERBα and REV-ERBβ. It is used in laboratory studies of circadian biology and metabolism, not as an approved medicine. It is also known by the informal name Stenabolic.

Is SR9009 approved for human use?

No. SR9009 has not been approved as a therapeutic drug in the United States, European Union, or other major markets. Human safety and efficacy data are very limited. Its presence in consumer products does not imply regulatory approval.

Why is SR9009 banned in sport?

The World Anti-Doping Agency lists SR9009 as a prohibited substance because it can alter gene expression and metabolic pathways relevant to performance. The ban applies at all times, not only during competition. Detection relies on laboratory methods such as mass spectrometry.

How is SR9009 detected in samples?

Laboratories commonly use liquid chromatography coupled with mass spectrometry to detect SR9009. The method can identify the compound and estimate concentration in a sample. Detection limits depend on the matrix and instrument.

Network